: Test that the system successfully disables crane functions during an overload condition.
: Remove old wires from the terminal block and connect the new assembly.
Detailed wiring diagrams and flowcharts can be found in the PAT DS350 Service Manual or via WIKA Mobile Control Support . LENGTH-ANGLE-RADIUS-LOAD INDICATING SYSTEM
: Lower the boom completely to remove rest pressure. Disconnect hydraulic hoses.
: Fully retract the boom. Turn the potentiometer counter-clockwise until it stops to reset the "zero" point.
: Reconnect hoses and bleed the air from the hydraulic lines to ensure accurate readings. ⚠️ Critical Safety Checks